Application field
Used for iron tower (power, communications, microwave, etc.), the chimney (power plant, coking plant, chemical plant, etc.), high building, airport clearance area, large Bridges, large port machinery, large engineering machinery, such as wind turbines need to have the occasion of the warning role on aircraft.
The main functions and characteristics
Based on LED technology, conform to the standardization of optical design.
• built-in LED protection circuit, stable work, save maintenance costs.
Professional, optical processing and good heat dissipation design, effective guarantee luminous effect and service life.
Driven by constant current design, the effective protection of circuit with high reliability.
• import LED light source, effectively guarantee the super long working life and energy conservation and environmental protection.
, shock resistance, corrosion resistance, impact resistance, damp and hot resistance, high and low temperature resistance.
And installation surface by bolted flange plate, base, easy to install.
Main technical parameters
Reference standard: ICAO (no. 14, with about) highlights strong obstacle lights and FAA - L856 standard
The vertical light Angle: 3 ° ~ 7 ° Min
High power high brightness LED light source
The level of light Angle: 360 °
Light color: white
Flash frequency: 20 ~ 60 times/min
Working voltage AC110-240 (special voltage can be customized)
Flash duration: 150 + 20 ms
Power consumption: ﹤ 30 w (30 times/min)
Light life: p 100000 h
The effective intensity: 2000 ~ 200000 CDS
Light-operated switch controlled illumination: 50 lux
Working temperature: - 40 ℃ ~ + 70?? C
Protection grade: IP65 (customizable)
Working humidity: 10% ~ 95% (condensation)
The reference weight: 5.0 kg
Material is qualitative
Body: aluminum alloy, chimney: Neil lens
Using range: 150 m ≦ H
Install and use method
, please install the lamp on the plane, and the plane has enough strength; If not installed flat mounting bracket can be customized according to specific circumstances.
When installation, do not use the photoelectric control baldheaded near to the light source; While ensuring the photosensitive head not be nearby objects.
Before connection, please make sure the power supply voltage is the same as the voltage of lamps and lanterns.
, lamps and lanterns before delivery will configure 0.5 meters of cable, according to the customer site to install the wiring.
, check the wiring is correct before switching power supply, lamp began to work.
Matters needing attention
Thisproduct work when there will be a temperature rise, belongs to the normal situation.
• non-professional maintenance personnel, please do not open any part of the lamp body, prevent to get an electric shock risk.
, this product is a sealing structure, do not open it, otherwise, the company will not be warranty.
Common place: